Products
Contact Us
- Contact Person : Ms. lily yang
- Company Name : shenzhen must power limited
- Tel : 86-0755-29109522
- Fax : 86-0755-29022690
- Address : ,,
- Country/Region : China
Low frequency power star power invertor 1500 watt
Product Detailed
Related Categories:Inverters & Converters
1.invertor 1500 watt
2.12v/24v/48V inverter
3,Input voltage :145-275Vac
4.AVR function
Low frequency power star power invertor 1500 watt
Main features:
1.Input voltage range: 145 ~ 275VAC
2.Rated capacity: 1-4KW
3. Output voltage: Same as mains input voltage4. Output frequency: 50 Hz+/-0.1Hz
5. Battery voltage: 24V/48Vdc
6. Wave form: Modified sine wave7. Transfer time: ≤5ms 8. Charging period: 8~12hours
9. Battery type: External Lead Acid Battery
Technology Specification:
MODEL | 115V Models | 230V Models | |
OUTPUT | |||
Power Levels crated at | 1000W,1500W,2000W,3000W,4000W | 1000W,1500W,2000W,3000W,4000W | |
Output Voltage | 100V/110V/120V(+/-10%) Selectable | 220V/230V/240V(+/-10%) Selectable | |
Voltage Waveform | Pure Sine wave | ||
Crest Factor | 3:1 | ||
Output Frequency | Auto Select for 50/60Hz | ||
(Synchronized to Mains) | 47Hz ~ 55Hz for 50Hz nominal | ||
56Hz ~ 65Hz for 60Hz nominal | |||
Regulation (Nominal) | ±10% typical of nominal voltage | ||
Regulation | ±3% of selected output voltage (adjustable with the | ||
(Battery mode) | remote set-up software) | ||
Transfer time | Blackout 3ms typical | ||
Brownout 1ms typical | |||
Battery mode to Normal mode??1ms typical | |||
Over current protection | Over load alarm level 100% ~ 120% | ||
Over load shutdown level 120% ~ 190% | |||
(Adjustable by using the remote set-up software) | |||
INPUT | |||
Nominal Voltage | 100V/110V/115V/120V Selectable | 200V/220V/230V/240V Selectable | |
Input Frequency | 47Hz ~ 65Hz, 50/60Hz auto-sensing | ||
Efficiency (Normal mode) | 97% | ||
Noise Filtering | Full time EMI/RFI filtering | ||
Voltage Range | 75V ~ 155V | 145V ~ 310V | |
AVR Range(2 Bucks, 2 Boosts) | Enhanced Buck: +28% of selected nominal voltage | ||
Buck mode: +10% of selected nominal voltage | |||
Boost mode: -10% of selected nominal voltage | |||
Enhanced Boost: -25% of selected nominal voltage | |||
Surge Protection | 424 Joules | ||
BATTERY | |||
Battery type | Lead-Acid 50Ah to 500Ah (Recommended) | Lead-Acid 50Ah to 500Ah (Recommended) | |
Voltage | 1000W:12/24VDC; 1500W-2000W:24/48VDC; 3000W-4000W:48VDC | ||
Typical backup time | No Limit | ||
Charging method | Quick charging when battery is not fully charged, | ||
trickle charging when battery is 90% fully charged. | |||
Maximum charging current | 15-25amp(MAX) | ||
Average charging | Quick charging mode:14V maximum. | ||
voltage for each battery | Trickle charging mode:13.5V (adjustable with the remote set-up software) | ||
Protection | Over current protection & Over charging voltage protection (SCR control) | ||
Thermal protection (CPU control) | |||
When temperature inside the unit is over 45 °C, charger will stop charging for 2 minutes followed by an 2 minutes charging. The cycle will be repeat | |||
Monitoring | Smart monitoring & warning for failed battery or open-circuit battery. | ||
Auto-detection each time when power on or every 6 days. | |||
SOLAR CHARGER(OPTIONAL) | |||
Rating voltage | 12V / 24V / 48V | 12V / 24V / 48V | |
DC input range | 12V model : 12 ~ 21Vdc | ||
24V model : 24 ~ 42Vdc | |||
48V model : 48 ~ 84Vdc | |||
Charging method | Constant voltage with current limiting by PWM control | ||
Charging voltage | 12V model :13.5Vdc | ||
24V model : 27.0Vdc | |||
48V model : 54.0Vdc | |||
Power rating | 12V model : 13.5Vdc @ 37A | ||
24V model : 27.0Vdc @ 37A | |||
48V model : 54Vdc @ 18.5A | |||
Protection | DC input polarity protection, DC input short circuit protection( when battery is | ||
connected), DC output over current protection | |||
COMMUNICATIONS & MANAGEMENT | |||
Standard Interface port | UPSilon2000 compatible; optional for RS232 . | ||
Optional Interface part | RJ45 (Surge protection), DB9, | ||
Control panel | LCD or LED Selectable | ||
Audible alarm | Alarm on battery:Low battery & Battery over voltage | ||
Alarm on abnormal operation:Over load, Short-circuit, & Over heat | |||
Green mode function | 1% to 14% of full load (adjustable by using the remote set-up software) | ||
(Auto-shut-off in blackout) | The default setting is OFF. | ||
Cooling fan control | Auto on / off, controlled by temperature & operation mode | ||
ENVIRONMENTAL AND SAFETY | |||
Operating Temperature | Up to 1500 meters:0 °Cto 40°C (32°F to 104°F) | ||
Transit/storage Temp. | 15°C below zero to 55°C (5°F to 131°F) | ||
Relative Humidity | 5 - 95% non condensing | ||
Operating Altitude | 0 ~ 3000 meters | ||
Quality control system | ISO 9001:2000, ISO 14002-2004 | ||
PHYSICAL | |||
Appearance | product size(mm) | 1000W-1500W:452×192×338MM | |
2000W-4000W:500×260×455MM | |||
Weight(Kg) | 1KW:14.0kg;1.5kw:25.0kg;2kw:28.0kg:3kw:30.0kg;4kw:35.0kg | ||
Carton Gross Weight | 1KW:15.0kg;1.5kw:27.0kg; 2kw:31.0kg; 3kw:36.0kg;4kw:41.0kg |
Low frequency power star power invertor 1500 watt
Other products