off grid solar inverter
Product Detailed
Related Categories:Inverters & Converters
*charging current adjustable
*lcd panel--new
*RS232 port optional
*low frequency, two boards inside
*updated mosfets
off grid solar inverter
120V Models | 230V Models | ||
OUTPUT | |||
Power Levels crated at nominal inputs | 1KW;2KW;3KW;4KW | 1KW;2KW;3KW;4KW;5KW;6KW | |
Output Voltage | 100V/110V/120V Selectable | 220V/230V/240V Selectable | |
Voltage Waveform | Pure Sine wave | ||
Crest Factor | 3:'1 | ||
Output Frequency | Auto Select for 50/60Hz,47Hz ~55Hz for 50Hz nominal,56Hz ~ 65Hz for 60Hz nominal | ||
(Synchronized to Mains) | |||
short circuit protection | Circuit breaker | ||
Over load protection | Circuit breaker | ||
Capable of motor | 1kw/2kw: 1HP, 3kw/4kw: 2HP, 5kw/6kw 3HP | ||
Transfer time (DC to AC) | 10 ms | ||
protection | Over load protection | ||
Over temperature protection | |||
Output short circuit protection | |||
INPUT | |||
Nominal Voltage | 100V/110V/120V Selectable | 220V/230V/240V Selectable | |
Input Frequency | 40Hz ~ 80Hz, 50/60Hz auto-sensing | ||
Efficiency (Normal mode) | 95% | ||
Noise Filtering | Full time EMI/RFI filtering | ||
Inverter breaker size | 1kw: 10A, 2kw-6kw:30A | 1kw: 10A, 2kw-6kw: 30A | |
Voltage Range | 100V ~ 127V | 155V ~ 265V | |
Inverter main features | low frequency | ||
huge charge current | |||
pure copper transformer | |||
supports inductive loads | |||
Surge Protection | 1KW/ 2KW:416 Joules | 1KW-3KW:430 Joules | |
3KW ~ 4KW:724 Joules | 4KW-6KW:826 Joules | ||
BATTERY | |||
Battery type | Lead-Acid 50Ah~500Ah (Recommended) | Lead-Acid 50Ah~500Ah (Recommended) | |
DC Voltage | 1KW/2KW/3KW:12Vdc | 1KW/2KW/3KW:12Vdc | |
2KW/3KW/4KW:24Vdc | 2KW/3KW/4KW:24Vdc | ||
3KW/4KW:48Vdc | 3KW/4KW/5KW/6KW:48Vdc | ||
Typical backup time | Up to external battery | ||
Charging method | Battery charger: (bulk,absorption, and float) | ||
charge current is adjustable: 25% 50% 75% 100% optional | |||
Maximum charging current | 1000W 12V:35A | 2000W 12V:65A | |
2000W 24V:35A | 3000W 12V:65A | ||
3000W 24V:45A | 4000W 48V:35A | ||
5000W 48V:40A | 6000W 48V:50A | ||
Average charging | Quick charging mode:15.7V-54V maximum. | ||
voltage for each battery | Trickle charging mode:13.5V -52V(adjustable with the remote set-up software) | ||
Protection | Over current protection & Over charging voltage protection | ||
Battery over voltage & low voltage protection | |||
When temperature inside the unit is over 45°C ,charger will stop charging for 2 minutes followed by an 2 minutes charging. The cycle will be repeate | |||
Monitoring | RS232 communication port | ||
remote control cable 10 meters | |||
SOLAR CHARGER | |||
Rating voltage | 12V / 24V / 48V | 12V / 24V / 48V | |
DC input range | 12V model : 12 ~ 21Vdc;24V model : 24 ~ 42Vdc;48V model : 48 ~ 84Vdc | ||
Charging method | Constant voltage with current limiting by PWM control | ||
Charging voltage | 12V model:13.5Vdc;24V model: 27.0Vdc;48V model: 54.0Vdc | ||
Power rating | 12V model : 1000W/2000W (13.5Vdc @ 37A) | ||
24V model : 1000W/2000W (27.0Vdc @ 37A) | |||
48V model : 3KW/5KW/6KW (54Vdc @ 18.5A) | |||
Protection | DC input polarity protection, DC input short circuit protection( when battery is | ||
connected), DC output over current protection | |||
COMMUNICATIONS & MANAGEMENT | |||
Standard Interface port | RS232 | ||
Optional Interface part | RJ45 (Surge protection), DB9 | ||
Control panel | LED/LCD optional | ||
Audible alarm | Alarm on battery:Low battery & Battery over voltage | ||
Alarm on abnormal operation:Over load, Short-circuit, & Over heat | |||
Green mode function | 1% to 14% of full load (adjustable by using the remote set-up software) | ||
(Auto-shut-off in blackout) | The default setting is OFF. | ||
Cooling fan control | Auto on / off, controlled by temperature & operation mode | ||
ENVORMENT AND SAFETY | |||
Operating Temperature | Up to 1500 meters:0°C to 40°C (32°Fto 104°F) | ||
Transit/storage Temp. | -15°C to 55(5°F to 131°F) | ||
Relative Humidity | 5 - 95% non condensing | ||
Operating Altitude | 0 ~ 3000 meters | ||
Quality control system | ISO 9001:2000, ISO 14002-2004 | ||
PHYSICAL | |||
Appearance | Size(mm)LxWxH | 580*315*300 | |
G.W(Kg) | 1000W/19kg ;2000W/24kg ;3000W/28kg | ||
Size(mm)LxWxH | 755*319*288 | ||
G.W(Kg) | 4000W/38kg ;5000W/49kg ;6000W/49kg |